May 15, 2013 002-1362, Rev. D, US Page 1 of 3
Compatible External Printers
Printers with the following specifications are compatible with the ZOOM LATITUDE
programmer:
•
Manufactured by Hewlett-Packard, Brother, or Samsung
•
Uses a PCL5 compatible language
(PCL5, PCL5e, and PCL5c)
•
Uses a parallel port connector or USB port connector. NOTE: The required
external connector type varies by pulse generator software application (Tables
1 and 2). Both connector types are required to be able to print externally to the
entire list of BSC products referenced.
Printers with other specifications may be compatible; however BSC has not
performed any additional compatibility testing.
Printing via an External Printer
To print via an external printer, the printer cable must be connected to the
appropriate connector on the left side of the programmer (Figure 1) and the printer
must be turned ON.
There are two options to print. Reports may be printed while actively interfacing with
the patient’s device, referred to as a ‘patient/disk session’ or reports may be printed
after the patient/disk session, through the Patient Data Management Utility.
While actively interfacing with the patients device, select Utilities/Print or the Print
icon or Reports > select External printer > select desired reports > select Print.
Table 1 shows the connector type required for each pulse generator family to print
to an external printer from within a patient/disk session.
Table 1. Print External by Connector Type - Patient/Disk Session
Family Parallel Port
USB
None
EQUIO
TM
, ADVANTIO
TM
, INGENIO
TM
, VITALIO
TM
, FORMIO
TM
, INVIVE
TM
,
INTUA
TM
, INLIVEN
TM
PUNCTUA
TM
, ENERGEN
TM
, INCEPTA
TM
, COGNIS
®
, TELIGEN
®
X X
ALTRUA
®
, INSIGNIA
®
, NEXUS
®
, CONTAK RENEWAL® TR / TR2
VITALITY
®
,
VITALITY 2, VENTAK
®
PRIZM
®
, VENTAK PRIZM 2
X
CONFIENT
®
, LIVIAN
®
, CONTAK RENEWAL
(3/4/4AVT
®
), VITALITY
®
DR HE
X
Alternatively, if data has been saved to the programmer hard drive or to a USB pen
drive, printing to an external printer can be initiated from the Patient Data
Management Utility (Figures 2/3). From the programmer startup screen, select the
Patient Data Management Utility > Select the Print Tab > select patient records and
desired reports > select Print. Table 2 shows the connector type required for each
pulse generator family to print to an external printer from within the Patient Data
Management Utility.
Table 2. Print External by Connector Type - Patient Data Management Utility
Family Parallel Port
USB
None
EQUIO, ADVANTIO, INGENIO, VITALIO, FORMIO, INVIVE, INTUA,
INLIVEN, ALTRUA, INSIGNIA, NEXUS, CONTAK RENEWAL TR / TR2
PUNCTUA, ENERGEN, INCEPTA, COGNIS, TELIGEN, CONFIENT, LIVIAN,
CONTAK RENEWAL 3/4, VITALITY DR HE, VITALITY, VITALITY 2, VENTAK
PRIZM , VENTAK PRIZM 2
X X
PULSAR MAX
®
, PULSAR MAX II, DISCOVERY
®
, DISCOVERY II,
MERIDIAN
®
, CONTAK RENEWAL 4AVT
X
A Closer Look
®
®
The Model 3120 ZOOM
®
LATITUDE
®
Programmer Recorder Monitor
includes a built-in printer to print
reports / data from the implanted
pulse generator (PG). However, it
may be preferred to print reports on
conventional-sized paper, which can
be accomplished by using an external
printer.
This article focuses on printing to a
compatible optional external printer.
Products Referenced
Model 3120 ZOOM
®
LATITUDE
®
Programmer Recorder Monitor (PRM),
ICDs, CRT-Ds, CRT-Ps and Pacemakers
in Tables 1 and 2
Products referenced herein may not be
approved in all geographies. For
comprehensive information on device
operation, reference the full instructions for
use found at: www.bsci.com/ifu.
CAUTION: Federal (U.S.) law restricts this
device to sale by or on the order of a
physician.
All graphics produced by Boston Scientific
Corporation, unless otherwise noted.
CRT-D: Cardiac Resynchronization Therapy Defibrillator
CRT-P: Cardiac Resynchronization Therapy Pacemaker
ICD: Implantable Cardioverter Defibrillator
S-ICD: Subcutaneous Implantable Defibrillator
Contact Information
Americas
(Caribbean, and Central, North, and South America)
www.bostonscientific.com
Technical Services
LATITUDE
®
Clinician Support
1.800.CARDIAC (227.3422)
+1.651.582.4000
Patient Services
1.866.484.3268
Europe, Middle East, Africa
Technical Services
+32 2 416 7222
eurtechservice@bsci.com
LATITUDE Clinician Support
Asia Pacific
Technical Services
+61 2 8063 8299
LATITUDE Clinician Support
latitude.asiapacific@bsci.com
japan.latitude@bsci.com (Japan)
© 2013 by Boston Scientific Corporation
or its affiliates.
Comentários a estes Manuais